Centrala FS4000/8 este conceputa pentru a functiona cu senzori de incendiu conventionali si puncte de apel manual pe 8 zone. Panoul beneficiaza de iesiri pentru dispozitive active externe.

Specificatii tehnice:

Numar zone

Numarul maxim de detector intr-o zona: 32

Rezistenta maxima pe o zona: 100 Ohmi

 

Consum energetic

 In conditii de avarie: 0-6mA

In conditii normale: 6-16mA

In conditii de incendiu: 16-80mA

La scurt circuit: >80mA

 

Performanta:

-        Control pe zonele de alarma si iesiri controlabile in conditii de avarie (scurt circuit si intrerupere) si resetare automata

-        Detectia sau inlaturarea senzorului si resetarea automata

-        Identificarea punctelor de apel manual

-        Iluminare LED pentru starea de alarma si urgenta

-        Intarziere a iesirilor pentru conditii de incendiu pentru o perioada de 1 pana la 7 minute dupa inregistrarea starii de incendiu

-        Indicatie stare dispozitiv pentru transmiterea de date prin RS-485

-        Incorporat buzzer pentru conditii de incendiu, dar si pentru conditii de avarie

Specificatii tehnice detaliate:

 

Fire alarm lines:

   - Maximum number of fire detectors in a line

   - Connecting line

   - Maximum resistance of a line

Current thresholds for:

   - Fault condition

   - Duty mode

   - Fire condition

   - Short circuit

Monitored outputs for fire condition:

   - Number

   - Type

   - Electrical characteristics

 

Relay outputs for fire condition:

   - Number

   - Type

   - Electrical characteristics

 

Relay output for fault condition:

   - Number

   - Type

   - Electrical characteristics

 

Relay output for fault condition:

   - Number

   - Type

  

 

 - Electrical characteristics

 

 

 

32

 two-wire

100 

 

0 – 6 mA

6 – 16 mA

16 – 80 mA

> 80 mA

 

- 2 pcs

-potential, relay with independent control

- (19-27.5)V DC/1 A

 

 

- 2 pcs

- potential-free,1 switching,     1 NO

- 3А/125V AC, 3A/30V DC

 

 

-  1 pcs

- potential-free, switching

- 3А/125V AC, 3A/30V DC

 

 

- 1 pcs.

- none-monitored type activated on short-circuit (from potential free contact)

- 5 VDC on normal open state

- 0 VDC in activation mode

 

Performance:

-    Control over fire alarm lines and controllable outputs for fault conditions (short circuit and interruption) and automatic reset.

-    Detection of removed fire detector and automatic reset.

-    Identification of manual call points.

-    LED indication for alarm state and emergency.

-    Delay of outputs for fire condition with time period of 1, 2, 3, 4, 5, 6  or 7 minutes after fire condition is registered.

-    Option for ''LOGICAL AND '' realization of two fire alarm lines.

-    Duty Mode condition with direct activation of Fire Condition 2nd Stage '' for two fire alarm lines.

-    Status Indication of the device for data transmission RS485.

-    Option for switching  on/off  interface RS485 communication.

-    Built-in sounder for fire condition – one tonal, continuous, can be switched off.

-    Built-in sounder for fault condition – one tonal, discontinuous, can be switched off.

-    Test mode for fire alarm lines.

-    Disabling fire alarm lines.

-    Disabling outputs for fire condition.

-    Expanding the options by means of extra relay outputs for fire condition for each line and built-in RS485 for operation in a local network.

- Input for remote Reset fires operation;

 

Indications of registered events:

   - Light indication

   - Sound

Power supply

   - Mains:

          Voltage

          Frequency

   - Backup batteries:

          Battery type

          Number of batteries

          Nominal voltage of the backup battery

          Nominal capacity C20

          Charge voltage

 

 

- LED

- Built-in buzzer

 

 

(100-240)V AC

50/60 Hz

 

lead, gel electrolyte

2 pcs

12V

(4,5) Ah

28V DC

          

Operation in Duty mode upon interruption in main power supply:

                              

2 lines

4 lines

6 lines  

8 lines

24V / 4,5Ah

    120 h

      98 h

      80 h

      68 h

                        24V / 1,2Ah

                             32 h

                             24 h

                             20 h

                             16 h

 

Consumption on backup batteries supply:

Configuration of 2 lines

Configuration of 4 lines

Configuration of 6 lines

Configuration of 8 lines                

 

Power supply to external devices:

   - Voltage

   - Maximum current value (including current of contr.outputs)

 

Fuses

- Main supply 230V - 4.0 A

- Backup battery - 6.0 A

- Power supply to external devices - 1.85 A automatic

- Monitored outputs - 1.1 A automatic

 

Dimension - 313mm х 218mm х 85mm

 

Weight (backup batteries not included) - 1,5 kg

< 35 mA at 24V DC

< 45 mA at 24V DC

< 55 mA at 24V DC

< 65 mA at 24V DC

 

 

(19-27)V DC

1,2A

 

 

 

 

 

 

Cumparati cu incredere!

Va oferim:

  • Livrare imediata din stoc, expeditie in aceeasi zi
  • Drept de retur extins 30 de zile
  • Satisfactie garantata

Expeditii si retururi

Totul foarte simplu

  • Serviciul de curierat este facultativ. Alegeti un curier din cei propusi sau oricare altul
  • Daca doriti sa returnati produsul, o puteti face intr-un interval de 30 de zile calendaristice, cu conditia ca acesta sa se afle in aceeasi stare in care a fost cumparat, fara urme de folosire.
  • Trimiteti produsul pe adresa noastra numai dupa ce ne-ati notificat, cititi "Termeni si conditii".

30 alte produse în aceeași categorie

Close